ASE DC-Powered Bell 202 Modem
Switch Settings for Both Rack Mount (5008) and Box Mount (5006) Modem
Bold indicates factory settings
Switch Usage Notes Position Value if ON
1 -1 dB
2 -2 dB
3 -4 dB
SW1 Transmit gain
0 to –31 dB
Add values for all switches in the ON position
4 -8 dB
JP7 JP7 removed -16 dB
1 2 msec
2 4 msec
3 8 msec
CD On Delay
Delay in setting RS-232 “CD” signal after carrier is
detected, 2 to 30 milliseconds
Add values for all switches in the ON position
At least one switch must be ON
4 16 msec
5 1 msec
6 2 msec
7 4 msec
SW3
soft-carrier
turn-off
Soft-carrier turnoff duration, 1 to 15 milliseconds
Add values for all switches in the ON position.
At least one switch must be ON
8 8 msec
1 0 msec
2 2 msec
3 4 msec
4 8 msec
5 16 msec
6 32 msec
7 64 msec
SW4 RTS/CTS
Delay between requesting RTS and granting CTS, 0 to
254 milliseconds or constant
If switch 1 is OFF, add values for all switches (2 to 8)
in ON position.
If all switches are OFF, CTS is constantly enabled
8 128 msec
Vista de pagina 0
1 2 3

Indice de contenidos

Pagina 1

Applied Systems Engineering, Inc. ASE DC-Powered Bell 202 Modem Switch Settings for Both Rack Mount (5008) and Box Mount (5006) Modem Bold ind

Pagina 2 - - 2

ASE DC-Powered Bell-202 Modem - 2 - Jumper Settings for Box Mount (5006) Modem Bold indicates factory settings Jumper Usage Notes Jumper Meaning

Pagina 3 - - 3

ASE DC-Powered Bell-202 Modem - 3 - Jumper Settings for Box Mount (5006) Modem Bold indicates factory settings Jumper Usage Notes Jumper Meaning

Comentarios a estos manuales

Sin comentarios